Uncategorized

Why Monitor Arms and Medical Devices Use Constant Force Springs: 7 Things Engineers Actually Care About

Target keyword: constant force spring vs gas spring / constant force spring for monitor arm

Title tag: Why Monitor Arms Use Constant Force Springs, Not Gas Springs

Meta: A 7-point engineering comparison of constant force springs and gas springs for monitor arms and medical devices: force curve, sealing, temperature, size, travel, cost and maintenance.

CTA positions: After comparison table / after design notes / end (3 total)

If you are designing a monitor lift arm, a height-adjustable table or a medical device counterbalance, you have almost certainly wrestled with the same question: gas spring or constant force spring?

For the last decade the gas spring was the default answer. More and more mechanical engineers are now switching. It isn’t because the technology is fashionable — it is because of a handful of very specific engineering realities, most of which become obvious only after you have been burned by a gas spring that sags after two years or stiffens in the cold.

1. The force curve is flat from day one — no “feel tuning” required

A gas spring generates force by compressing gas, so force rises as it compresses. The practical result is a mechanism that feels soft at the top of its travel and over-powered at the bottom. Many arm manufacturers try to hide this with friction washers — which introduces stiction and, once the washer wears, a slow drop.

A constant force spring produces an essentially horizontal force line through the middle of its travel. The lift feels identical everywhere, and the mechanism does not depend on friction damping to hold position.

2. No seal means no “sags after two years”

Gas spring failure is remarkably predictable: seal ring wears → gas escapes slowly → support force falls year on year → the monitor starts sliding down on its own. Heat, frequent cycling and dust all accelerate it.

A constant force spring is a purely mechanical element. No gas chamber, no oil, no seal to degrade. Its loss of performance comes from metal fatigue — a process you can design against and predict, rather than a random leak.

3. It works across the temperature range

Gas spring force is noticeably temperature-dependent; in cold conditions the gas behaves differently and the spring stiffens. For medical equipment facing sterilisation, or outdoor installations facing winter, that is a real problem. The elastic modulus of spring steel changes very little over normal industrial temperature ranges, so a constant force spring behaves consistently across the operating envelope.

4. It fits where a gas spring cannot

Unrolled, a constant force spring is a thin strip; coiled, it is a flat disc. It needs only a narrow slot to run in. A gas spring is a cylinder and needs pivot points at both ends, which sets a floor on both volume and travel ratio. For genuinely slim lift mechanisms this is frequently the deciding factor.

5. Travel can be much longer

The spring outputs unrolled length, and usable travel generally reaches 70–80% of the total strip length. Out of a coil the size of your fist, you get considerably more lift travel than from a gas spring of comparable bulk.

6. More predictable cost and better batch consistency

Gas spring cost is exposed to gas-charge consistency and seal quality, and batch-to-batch force variation regularly causes headaches on the assembly line. Constant force spring cost is driven mainly by material and tooling, and once the specification is fixed, batch consistency can be held in a narrow band — which matters greatly for automated assembly.

7. Easier to service and to recycle

A gas spring that loses pressure can only be replaced as a unit, and disposing of it means handling a pressure vessel separately. A constant force spring is a single metal component: simple to swap, and directly recyclable — a genuine advantage for products exported into the EU with environmental compliance requirements.

The comparison at a glance

CriteriaConstant force springGas springExtension springTorsion spring
Force characteristicNear constantRises with travelRises linearly with travelRises linearly with angle
Hold anywhereStraightforwardNeeds friction assistDifficultDifficult
Long travelStrong (up to 80% of unrolled length)ModerateWeakWeak
Leak riskNoneYesNoneNone
Temperature sensitivityLowHighLowLow
VolumeSmall and flatLarge cylinderModerateSmall
Failure modeFatigue, predictableLeakage, randomFatigueFatigue
Service costLow — replace one partHigh — replace whole unitLowLow

Designing an arm or a lift mechanism right now?

Send us load weight, lift travel and available space. We will tell you whether a constant force spring can replace your gas spring, and what thickness and width you need.

Five things designers most often overlook

  1. Do not use the full travel. Keep working travel within 70% of unrolled length. The margin you leave at the end is the margin that gives you life.
  2. Keep the strip path clear. If the strip rubs the housing or tracks off-centre it will score quickly, and a score line is a fatigue crack waiting to happen.
  3. Let both ends rotate freely. If the ends are rigidly locked, the strip’s natural tendency to twist converts into lateral stress — the most common cause of end-region breakage.
  4. Design in a return stop. A constant force spring always wants to rewind. Without a limit the strip can snap back violently when released.
  5. Agree a decay specification with your supplier. The professional phrasing is “no more than X% force loss after Y cycles at Z stress”. The more specific your question, the faster you filter out suppliers who are guessing.

Ask this one question and save yourself a lot of trouble“Can you supply samples in two or three different thicknesses at the same dimensions so I can measure the force curve myself?” A manufacturer willing to let you test first — and able to explain how thickness shifts the curve — is a manufacturer who knows the process.

Prototype first, negotiate price second

Bowin Spring has been making constant force springs for 10 years. We supply multiple thicknesses for side-by-side testing, so you decide with measured data instead of guesswork.

Share it :