A power spring — also called a clock spring, mainspring or spiral torsion spring — is a flat strip of spring steel wound into a plane spiral that delivers torque through rotation. The key distinction from a constant force spring is the output form: a constant force spring pulls in a straight line, a power spring turns a shaft.
Power springs have the widest application base of the three families. Seat belt retractors, recoil starters, clothes-drying racks, timers, door closers and rehabilitation equipment all rely on them. They are also the easiest family to specify incorrectly, because they add two extra dimensions to the problem: turns and end configuration.
How much torque, and over how many turns?
Give us required torque, number of turns and available space (ID × OD × width). An engineer will come back with a selection. Reply within 2 hours on business days.
1. Calculating torque
Within its elastic range, a spiral torsion spring produces torque approximately proportional to deflection angle:
M ≈ ( E × b × t³ × θ ) / ( 12 × L )
Where M is torque (N·mm), E is elastic modulus (N/mm²), b is strip width (mm), t is strip thickness (mm), θ is deflection angle (radians) and L is total unrolled strip length (mm).
A worked example
Suppose you need 300 N·mm of torque after 3 turns (θ = 3 × 2π ≈ 18.85 rad), with room for a 10 mm wide strip, using 65Mn spring steel (E ≈ 206,000 N/mm²) and a total strip length of 600 mm.
- Substitute: 300 = (206,000 × 10 × t³ × 18.85) / (12 × 600)
- Rearrange: t³ ≈ 300 × 12 × 600 / (206,000 × 10 × 18.85) ≈ 0.00558
- Cube root gives t ≈ 0.177 mm
So a 0.18 mm thick, 10 mm wide, 600 mm long 65Mn power spring lands close to target. Prototype at 0.17 / 0.18 / 0.20 mm, measure the torque curve, then lock it in.
Why power springs are harder to calculate than constant force springsA power spring’s torque changes with how many turns it has already turned — and more importantly, pre-tension has an enormous effect. The same spring, wound half a turn further during assembly, produces an entirely different torque curve. So: the formula sets direction, prototyping sets the parameters, and assembly process decides the final behaviour. None of those three steps can be skipped.
2. End configurations: the most overlooked decision
End configuration determines how the spring is fixed and how it transmits force. Choose badly and you get slipping, stress concentration, or outright breakage.
| Position | Type | Characteristics | Typical use |
|---|---|---|---|
| Inner end | Inner hook | Hooks into a slot on the shaft; easy to assemble | The most common general-purpose option |
| Inner bent tab (L-shape) | Tab engages a hole in the shaft; reliable force transfer | Higher torque where slipping must not occur | |
| No hook (free inner end) | Relies on winding pre-tension and friction | Miniature springs, extremely tight spaces | |
| Outer end | Outer hook | Hooks over a lug in the housing | General purpose, simple assembly |
| Straight outer end | Slots directly into a straight groove | Strong housings carrying high load | |
| Outer loop / eye | End rolled into a loop over a post | Allows a small amount of angular movement, reducing stress concentration |
Selection principle: the more direct the load path, the more reliable the transfer — but the greater the stress concentration. For high torque, favour a bent tab or straight end. For long life, favour a hook or loop that can pivot.
3. Material selection
| Material | Strength | Corrosion | Cost | Typical use |
|---|---|---|---|---|
| 65Mn spring steel | High | Fair (needs plating) | Low | Recoil starters, drying racks, door closers — indoor, high torque |
| 60Si2MnA | Very high | Fair | Medium | High-stress, high energy-storage applications |
| 301 stainless | High | Good | Medium-high | Seat belt retractors, medical devices, precision instruments |
| 304 stainless | Medium | Excellent | Medium-high | Damp, outdoor and hygiene-critical environments |
| Carbon tool steel | High | Poor | Low | Watches, timers, miniature springs |
Not sure which end configuration or material?
Send a message with torque requirement, turns, shaft diameter and housing dimensions. We will return a complete selection proposal including the end configuration — and the torque curve you should expect.
4. Four common failure modes
- Insufficient torque, weakening over time — usually working stress has exceeded the material’s elastic limit, causing permanent deformation. Root cause is often a strip chosen too thin, or excessive pre-tension.
- Breakage near an end — stress concentration, typically from too small a bend radius at the end fitting or a fixing point that cannot rotate.
- Slipping, will not carry the load — end configuration mismatched to the shaft or housing, so the load-bearing contact area is too small.
- Fatigue fracture mid-strip — a score, corrosion pit or material inclusion acting as a crack initiation site.
5. Life design: how to discuss it with a supplier
There is no single “standard” power spring life. It depends on working stress, deflection amplitude, environment and surface quality. So the professional conversation is not “how long will it last” but giving your operating conditions and asking for a corresponding cycle-count commitment:
- What is the maximum working torque, relative to the material’s limit?
- What is the deflection amplitude per cycle?
- How many cycles per day, and how many years must it survive?
- What are the ambient temperature, humidity and media?
Answer those four and a competent supplier can tell you a sensible design stress band and the verification standard they can meet.
6. Frequently asked questions
Q1: How many turns can a power spring handle?
It depends on unrolled strip length and the winding envelope. Several turns to around a dozen is typical. More turns means less usable torque per turn — a straightforward energy trade-off. Optimise turns and torque requirement together.
Q2: Does pre-tension affect torque?
Substantially. Pre-tension means the spring starts working from a non-free state, which shifts the entire torque curve. Pre-tension must therefore be specified on the drawing and in the assembly work instruction.
Q3: What is the difference between a power spring and a stainless constant force spring?
The output form. A constant force spring outputs linear pull; a power spring outputs rotary torque. Both can use 301 stainless, but the construction and end design are completely different and they are not interchangeable.
Q4: Can you make non-standard sizes?
Yes — power springs are inherently custom components. Thickness, width, unrolled length and end configuration can almost always be tailored to your space and torque requirement. The critical thing is describing the operating conditions clearly.
Q5: What are your prototyping and production lead times?
Standard materials sample in [LEAD TIME]. Production lead time depends on quantity and process complexity, and we state it explicitly on the quotation rather than quoting optimistically.
Send us the drawing. Our engineers take it from there.
A power spring is a fully custom component — you only need to state “how many turns, how much torque, how much space”. Torque design, end configuration, material and heat treatment come from our 10 years of process experience.